| Specification:
AC Input
|
Input Voltage (VAC) |
Current (PFC) |
Current (No PFC) |
|
180-250 47-63Hz |
6.6A |
10A |
|
90-140V 47-63Hz |
N/A |
20A |
Average Charging Rate 1000 J/s at rated Output Voltage.
Peak Charging Rate 1100 J/s at rated Output Voltage.
Standard Voltage Ranges 1, 1.5, 2, 3, 4, 5, 6, 10, 15, 20, 30, 40 kV. All models continuously variable from 0 to 100% of rated voltage output. Linear to within 1% of full scale. Accuracy 1% of rated.
Polarity Available as fixed Positive or Negative. Please specify.
High Voltage Assembly
|
Voltage |
Medium |
Output Cable |
|
1-6kV |
Air |
Coax RG 58 |
|
7-40kV |
Oil |
12AWG, HV Silicon Type DJ |
Input Connector VDE, UL, CSA, approved.
Power Factor
| |
Non PFC |
PFC |
|
All Models |
0.65 |
0.98 |
Efficiency Better than 85%
Stored Energy Less than 0.3 Joules all models.
Stability 0.2% per hour after 1 hour warm-up.
| Pulse to Pulse Repeatability +/-0.2% to 300 Hz. For higher repetition rates, consult factory
Temperature Coefficient 100 PPM per oC
Ambient Temperature Storage: -40 to +85 oC Operating:-20 to +45 oC
Humidity 90% Non-condensing
Protection The power supply is protected against open circuits, short circuits, overloads and arcs.
Agency Approvals Certified to meet UL 2601.1, EN60601.1 (TUV) Safety requirements.
Note For PFC Units When high voltage is enabled using either the "HV Enable" Line or de-activation of the "Inhibit" Line, the power supply will reach normal operation mode (and therefore all other published specifications) within 50 milli-seconds.
Mechanical 5.56"(141mm) x 5.75"(146mm) x 14.2"(361mm) Weight: 20lbs (9kg) See Datasheet.
Accessories - Detachable 8 feet HV cable - 15 pin "D" plug mating control connector - Operating manual
Remote Control Via 15pin d-type connector on rear panel. See Datasheet.
Options
| Suffix-LH |
"Low Inhibit" - A + 10 to 15 volt (high) signal will allow power supply operation. A 0 to +1.5 (low) signal will inhibit the supply. |
| Suffix-EN |
"Low Enable" - A + 10 to 15 volt (high) signal will disable power supply operation. A 0 to +1.5 volt (low) signal will enable the supply. |
| Suffix-5V |
0 to +5 volt program (0 to full-scale output) |
| Suffix-LP |
Latching overload protection | |