ALE Capacitor Charging Power Supply LC1202 Series. 1-30 kV, 12,000J/sec.FEATURES:
  • Repeatability <0.1% at repetition. rates to 1kHz
  • Water Cooled
  • Selectable 208 or 400VAC input
  • Sealed HV Assembly
  • Outputs to 30kV
The LC Series are a new design of compact water cooled power conditioning solutions for high performance HV Capacitor Charging applications requiring extremely low pulse to pulse repeatability. The LC1202 capacitor charging power supply is capable of delivering peak output charge rates of 13.5kJ/sec and average rates of 12kJ/sec. If used for DC applications the unit can continuously deliver 15kW power. The unique phase shifting inverter design enables the supply to charge capacitive loads with shot to shot voltage repeatability of 0.1% or better at repetition rates up to 1kHz.

The LC1202 shares elements of its topology with the XR series, but utilizes a brand new design of water cooled phase shifting resonant inverter. The use of a unique sealed water cooled HV tank assembly results in an 12kJ/second power supply in the same footprint as a standard 8kJ unit. The sealed HV tank also allows the unit to operate in any orientation unlike conventional oil insulated high voltage power supplies. Since the LC series does not require external air for cooling it is particularly suitable for installation in tight spaces, or in adverse environments. Lambda EMI is the only company currently offering this advanced performance in a compact 12kJ/sec water cooled package.
 

Specification:

AC Input
208 VAC or 400 VAC or 480 VAC,
3 phase, 50/60 Hz.
Field selectable with appropriate conversion kit 208/400
(VAC versions only).
(Please specify at the time of order).

Average Charging Rate
12,000 J/s at rated Output Voltage.

Peak Charging Rate
13,500 J/s at rated Output Voltage.

Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6,
10, 15, 20, 30 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.

Polarity
Available as fixed Positive or Negative, Please Specify.

High Voltage Assembly
Sealed silicone oil Insulated HV section with zero air.
Output Connector/Cable

Output Voltage 

Connector 

Cable 

1-30kV

Proprietary 

DS 2214SSJ 


Input Connector
VDE, UL, CSA, approved.

Power Factor
Passive PFC 0.85 min

Efficiency
Better than 85%

Stored Energy
Less than 0.3 Joules all models.

Stability
0.2% per hour after 1 hour warm-up.

 

Cooling
Flowed water at 2US GPM (7.6L/min) max. inlet temperature 35 degrees C. All water paths are at ground potential and are copper, brass or hydraulic hose. Connections via 12mm pipe to standard Swagelok type fittings on back of unit.

Pulse to Pulse Repeatability
+/- 0.1% to 250Hz standard.
+/- 0.1% to 1kHz option.

Temperature Coefficient
100 PPM per degrees C

Ambient Temperature
Storage: -40 to +80 degrees C
Operating:5 to +45 degrees C

Humidity
10-90% Non-condensing

Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.

Agency Approvals
Certification to EN60950 (pending)

Mechanical
19"(482mm) x 17"(432mm) x 8.75"(222mm)

Accessories

- Detachable 10 foot HV cable
- Operating manual

Remote Control
Via 25pin d-type connector on rear panel.

Click here for Remote Control details

Options

Suffix-RFI Optional external filter which reduces conducted emissions to meet VDE0871/6.78 Class B.
Suffix-5V  0 to +5 volt program (0 to full-scale output) 
Suffix-LP Latching overload protection 
Suffix-RS  Remote sense 
Suffix-CT Optional internal contactor for OEM only (standard on L/S models)
Ordering Information:

LC1202 L/S/OEM  10Kv  POS  208VAC  XX 
Model      Voltage    Polarity    Input Voltage    Options 
TDK-Lambda High Power/ALE

Other products:

 

SUPPORT DOCUMENTS

  • APP Note 500: Calculating Capacitor Charge Time
  • APP Note 502: Calculating AC Line Currents
  • APP Note 507: Charging Large Load Capacitors
  • APP Note 509: What is Regulation and Repeatability
  • APP Note 513: Power Factor Correction
  • APP Note 517: Protection against voltage reversal
  •