ALE Capacitor Charging Power Supply XR/XRDC Series. 1-30 kV, 6000J/secFEATURES:
  • Repeatability <0.1% at rep rates to 2kHz
  • Minimum stored energy
  • Unlimited parallel capability for higher power
  • Remote compatibility with 802 and 402
  • TUV safety approved

The XR Series are low cost solutions for high performance HV Capacitor Charging applications offering extremely low pulse to pulse repeatability. The XR-DC allows continuous DC operation with low ripple, and low stored energy. Employing Lambda EMIs patented phase shifting parallel resonant converter topology the XR series supplies offers unrivalled pulse to pulse repeatability at extreme repetition rates. Unlike other manufacturers who claim high performance in data sheets, the XR series has demonstrated 0.1% pulse to pulse repeatability at repetition rates to 2kHz, in real field applications.
 

Specification
AC Input
208 VAC or 400 VAC,
3 phase, 50/60Hz.
(Please specify at the time of order).

Average Charging Rate
6000 J/s at rated Output Voltage.

Peak Charging Rate
7000 J/s at rated Output Voltage.

Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6,
10, 15, 20, 30 kV.
All models continuously variable from 10 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.

Polarity
Available as fixed Positive or Negative.  Please specify.

High Voltage Assembly
Oil Insulated HV section with optional air insulation at voltages below 6kV

Output Connector/Cable

Output Voltage Connector Cable
1-6kV Amphenol HN RG-8/U
>6kV Proprietary DS 2214SSJ

Input Connector
VDE, UL, CSA, approved.

Power Factor
Passive PFC 0.85 min

Efficiency
Better than 85%

Stored Energy
Less than 0.3 Joules all models.

 

Stability
0.2% per hour after 1 hour warm-up.
Pulse to Pulse Repeatability
+/- 0.1% to 250Hz standard.
+/- 0.1% to 1kHz option.

Temperature Coefficient
100 PPM per oC

Ambient Temperature
Storage: -40 to +80 oC
Operating:0 to +45 oC

Humidity
10-90% Non-condensing

Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.

Agency Approvals
Certification to EN60950 (pending)

Mechanical
19"(482mm) x 17"(432mm) x 8.75"(222mm)

Accessories
- Detachable 10 foot HV cable
- Operating manual

Remote Control
Via 25pin d-type connector on rear panel.

 Suffix-RFI  Optional external filter which reduces conducted emission to meet VDE0871/6.78 Class B
 Suffix-5V  0 to +5 volt program (0 to full-scale output)
 Suffix-LP  Latching overload protection
 Suffix-RS  Remote sense
 Suffix-CT  Optional internal contactor for OEM only (standard on L/S models)

Ordering information:

 XR802

 L/S/OEM

 -

 1kV

 -

 POS

 -

 208VAC

 -

 XX

 Model

 

 

 Voltage

 

 Polarity

 

 Input Voltage

 

 Options

TDK-Lambda High Power/ALE

Other products:

 

SUPPORT DOCUMENTS

  • APP Note 500: Calculating Capacitor Charge Time
  • APP Note 502: Calculating AC Line Currents
  • APP Note 507: Charging Large Load Capacitors
  • APP Note 509: What is Regulation and Repeatability
  • APP Note 513: Power Factor Correction
  • APP Note 517: Protection against voltage reversal
  • ALE XR-XRDC Datasheeet
  •